ASTM E1725電氣系統(tǒng)元件耐火阻擋層系統(tǒng)耐火試驗標(biāo)準(zhǔn)試驗方法

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):53  分享到: 分享到騰訊微博
ASTM E1725電氣系統(tǒng)元件耐火阻擋層系統(tǒng)耐火試驗標(biāo)準(zhǔn)試驗方法
ASTM E1725 Standard Test Methods for Fire Tests of Fire-Resistive Barrier Systems for Electrical System Components
ASTM E1725電氣系統(tǒng)元件耐火阻擋層系統(tǒng)耐火試驗標(biāo)準(zhǔn)試驗方法

These fire-test-response test methods evaluate, under the specified test conditions, the ability of a fire-resistive barrier system to inhibit thermal transmission to the electrical system component within.
In these procedures, the specimens are subjected to one or more specific sets of laboratory test conditions. If different test conditions are substituted or the end-use conditions are changed, it is not always possible by or from these test methods to predict changes in the fire test response characteristics measured. Therefore, the results are valid only for the fire test exposure conditions described in these procedures.
These test methods provide a measurement of the transmission of heat to the electrical system components within the barrier system.
These test methods provide qualification of a fireresistive barrier system as one element of an electrical system designed to maintain continuous operation of critical functions and processes for a specific fire resistance rating.
In addition to the temperature data provided by these test methods, numerous other factors, such as referenced in 1.4 shall be considered in specifying such a system.
1. Scope
1.1 These test methods cover fire-test-response.
1.2 These fire-test-response test methods provide information on the temperatures recorded on the electrical system component within a fire-resistive barrier system during the period of exposure.
1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
1.4 Potentially important factors and fire characteristics not addressed by these test methods include, but are not limited to:
1.4.1 The performance of the fire-resistive barrier system constructed with components other than those tested.
1.4.2 An evaluation of the functionality of the electrical system within the fire-resistive barrier system.
1.4.3 An evaluation of the ampacity of the electrical system within the fire-resistive barrier system.
1.4.4 An evaluation of the smoke, toxic gases, corrosivity, or other products of heating.
1.4.5 A measurement of the flame spread characteristics over the surface of the fire-resistive barrier system.
1.4.6 An evaluation of through-penetration sealing methods.
1.4.7 Combustibility of materials in the fire-resistive barrier system or of the electrical system components.
1.4.8 The need for supports beyond those normally required.
1.4.9 Environmental conditions in the area of service.
1.5 The values stated in inch-pound units are to be regarded as the standard. The SI units given in parentheses are for information only.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
E119 Test Methods for Fire Tests of Building Construction and Materials
E1529 Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies
Index Terms
air drop; cable tray; conduit; electrical system components; fire resistance rating; fire-resistive barrier systems; fire-test-response method; junction box; open run cables; pull box; raceway; thermal transmission; Air drop; Cable tray; Conduits; Electrical systems; Fire endurance rating; Fire-resistant materials/testing; Fire-test response; Junction box; Open run cables; Pull box; Raceway; Thermal transmission properties
 

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 新址246正版资料免费大全二四六 | 2025澳门正版资料全年免费公开 | 2025澳门六今晚开奖结果:10 | 2025年澳门正版资料大全6149 | 澳门开门奖结果 | 2025年葫芦岛单位司机招聘信息 | 2025澳门码今晚开奖结果记录资料下载服务等 | 澳门最准最快资料 | 2025年澳门天天开好彩025期5 | 2025新奥开奖结果查询 | 2025年管家婆精准一肖 | 澳门宝典1166正规码 | 2025香港正版资料大全下载 | 三码必中| 2025新澳门原料免费大全 | 118彩图库主图118凤凰图下载 | 澳门彩正版资料免费公开2025年 | 澳门六开奖结果历史查询澳门天天开奖 | 澳门六开彩开奖结果记录 | 118论坛官方版下载 118论坛118图库彩图大全 | 2025年管家婆一肖中特 | 2025新澳今晚资料鸡号几号 | 最准一肖一码100%准 | 澳门最快最准的资料免费大全 | 澳门开奖结果开奖直播 | 澳门第072期资料 | 蓝月亮精选资料大全一首页 | 四肖八码期期准资料免费 | 彩库宝典原版1166 | 2025年新奥正版资料免费大全 | 2025025期真精华布衣123456 | 香港卡线上开通全攻略:轻松搞定 | 管家婆免费版最新版本安装下载 | 管家婆白小姐四肖四码 | 2025新奥最近开奖记录019期18 | 今晚开什么特马2025年 | 管家婆三期开一期精准是什么老张的智慧探索 | 今晚双色球最准一注预测号码 | 2025澳门今晚特马开什么 | 红姐彩色图库 | 今晚开奖免费查结果 |