ASTM C 1289貼面硬質泡沫聚乙氰尿酸酯隔熱板的標準規(guī)范

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數:203  分享到: 分享到騰訊微博
ASTM C 1289貼面硬質泡沫聚乙氰尿酸酯隔熱板的標準規(guī)范
ASTM C 1289 Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board
ASTM C 1289貼面硬質泡沫聚乙氰尿酸酯隔熱板的標準規(guī)范
 
This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as nonstructural panels useful in building construction. The materials are classified as follows: Types I, II, III, IV, and V. Under Type I are Classes 1 and 2. Under Type II are Classes 1, 2, and 3. Under Type II Class 1 are Grades 1, 2, and 3. Rigid polyisocyanurate thermal insulation boards shall be based upon the reaction of an isocyanate with a polyol, or the reaction of an isocyanate with itself, or both, using a catalyst and blowing agents to form a rigid closed-cell-structured polyisocyanurate foam. The insulation foam core shall be homogeneous and of uniform density. The following test methods shall be performed to conform to the specified requirements: conditioning; thermal resistance; compressive strength; dimensional stability; flexural strength; tensile strength perpendicular to board surface; water absorption; and water vapor transmission.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers the general requirements for faced thermal insulation boards composed of rigid cellular polyisocyanurate surfaced with other materials. The insulation boards are intended for use at temperatures between −40 and 200°F (−40 and 93°C). This specification does not cover cryogenic applications. Consult the manufacturer for specific recommendations and properties in cryogenic conditions. For specific applications, the actual temperature limits shall be agreed upon by the manufacturer and the purchaser.
1.2 This standard is intended to apply to rigid cellular polyurethane-modified polyisocyanurate thermal insulation board products that are commercially acceptable as non-structural panels useful in building construction. The term polyisocyanurate encompasses the term polyurethane. For engineering and design purposes, users should follow specific product information provided by board manufacturers regarding physical properties, system design considerations and installation recommendations.
Note 1—See Appendix X1 for guidance on determining wind pressure resistance of panels when required for wall sheathing applications.
1.3 The use of thermal insulation materials covered by this specification is typically regulated by building codes, or other agencies that address fire performance. Where required, the fire performance of the material shall be addressed through standard fire test methods established by the appropriate governing documents.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
Note 2—For conversion to metric units other than those contained in this standard, refer to .
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
C203 Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation
C208 Specification for Cellulosic Fiber Insulating Board
C209 Test Methods for Cellulosic Fiber Insulating Board
C303 Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation
C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C550 Test Method for Measuring Trueness and Squareness of Rigid Block and Board Thermal Insulation
C728 Specification for Perlite Thermal Insulation Board
C1045 Practice for Calculating Thermal Transmission Properties Under Steady-State Conditions
C1058 Practice for Selecting Temperatures for Evaluating and Reporting Thermal Properties of Thermal Insulation
C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
C1177/C1177M Specification for Glass Mat Gypsum Substrate for Use as Sheathing
C1303 Test Method for Predicting Long-Term Thermal Resistance of Closed-Cell Foam Insulation
C1363 Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus
D1621 Test Method for Compressive Properties of Rigid Cellular Plastics
D2126 Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging
E84 Test Method for Surface Burning Characteristics of Building Materials
E96/E96M Test Methods for Water Vapor Transmission of Materials
ANSI Standard
VoluntaryProductStan Performance Standard for Wood Based structural Use Panels
CAN/ULC Standard
CAN/ULC-S770-03 Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulating Foams
Index Terms
cellular plastic insulation; cellulosic fiber insulating board; composite foam insulation board; faced foam board; foam plastic insulation; oriented strand board; perlite board; polyiso board; polyisocyanurate; polyisocyanurate foam; polyurethane; polyurethane foam; thermal insulation; waferboard: Block and board thermal insulation--specifications; Board thermal insulation--specifications; Cellular thermal insulation--specifications; Cellulose fiber thermal insulation--specifications; Composite foam insulation board; Faced thermal insulation--specifications; Foam plastic insulation; Oriented strand board (OSB); Perlite thermal insulation--specifications; Polyurethane insulation--specifications; Rigid cellular polyisocyanurate; Rigid thermal insulation--specifications; Thermal insulating materials--specifications; Waferboard;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025年澳门正版免费;全面释义解释落实 | 管家婆一肖一码最准资料公开预包装食品 | 最新一期快乐大本营 | 澳门一肖一码一中一肖l新疆维吾尔自治区科技厅直属单位 | 新澳门资料大全正版资料查询 | 白小姐一肖一码期期准今晚 | 2025澳彩管家婆资料传真 | 一肖一码100% | 澳门资料大全正版 | 免费资料正版资料大全 | 2025270期澳门出码肖 | 2025全年免费资料大全 | 综合正版资料 | 管家婆一码中一肖2025 | 2025澳门免费资料精准 | 四不像正版+正版四不像灬 四不像正版+正版四不像 | 澳门一肖一码一必开一肖 | 管家婆正版全年免费资料 | 香港资料大全正版资料下载 | 澳门今晚必中一肖一码6149港奥彩 | 香港最快最准的资料 | 鲨鱼神算子激活码 | 49精准澳门彩最准确的 | 2025澳门特马图片 | 香港资料大全全年免费公开 | 49图库全新版本免费下载 | 中图库今日送一注 | 2025年澳门传真全集 | 香港金光佛316363 | 资料大全正版资料2025年 | 今晚四不像必中一肖图65期 | 香港最准最快资料今晚澳门必中一肖一码适囗务目 | 一码一肖100准| 澳门四肖八码期期准正版 | 2025年澳门资料天天开好彩免费大全 | 新2025年澳门全年精准资料大全 | 澳门一肖一码100%精准 | 澳门一肖一码准选今晚 | 香港资料大全正版资料使用方法官方版下载 | 今晚开什么码澳门今晚的结果 | 新澳门6合开彩开奖结果查询 |