新澳门免费资料大全最新版本更新内容-新澳门免费资料大全历史记录开马-新澳门免费资料大全历史记录开奖-新澳门免费资料大全精准版下-新澳门免费资料大全精准版-新澳门免费资料大全

阻燃防火材料-網上貿易平臺 | | WAP瀏覽
服務熱線:4006555305
當前位置: 首頁 » 防火測試中心 » 各國標準法規 » 美國 » 正文

ASTM D1230服裝紡織品易燃性標準測試方法

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:667  分享到: 分享到騰訊微博
ASTM D1230服裝紡織品易燃性標準測試方法
ASTM D1230 Standard Test Method for Flammability of Apparel Textiles
ASTM D1230服裝紡織品易燃性標準測試方法
Test Method D1230 cannot be recommended for the acceptance testing of commercial shipments since Federal regulations require apparel fabrics to meet the criteria of 16 CFR Part 1610 and correlation of test results with actual performance has not been established. Although Test Method D1230 is not recommended for acceptance testing, it is useful because it provides a less expensive and time consuming research tool than 16 CFR Part 1610.
In case of a dispute arising from differences in reported test results when using Test Method D1230 for testing of commercial shipments, the purchaser and the supplier shall conduct comparative tests to determine if there is a statistical bias between their laboratories. Competent statistical assistance is recommended for the investigation of bias. At a minimum, the two parties shall take a group of test specimens which are as homogeneous as possible and which are from a lot of material of the type in question. The test specimens shall be randomly assigned in equal numbers to each laboratory for testing. The average results from the two laboratories shall be compared using a nonparametric test for unpaired data and an acceptable probability level chosen by the two parties before testing is begun. If a bias is found, either its cause must be found and corrected or the purchaser and the supplier must agree to interpret future test results in light of the known bias.
All fabrics made of natural or regenerated cellulose, as well as many made from other natural or man-made fibers, are combustible. Some combustible fabrics when used for clothing are potentially dangerous to the wearer because of such factors as ease of ignition, flame spread time, amount of heat released, and design of the garment. This test measures two such factors: ease of ignition and flame spread time.
In order to place fabrics in one of the three flammability classes, arbitrary limits have been selected for time of application of the flame and for time of flame spread. These limits are based on extensive testing experience and are believed to be a useful guide in judging the relative flammability of apparel textiles. It must be understood, however, that no guarantee can be given and none is implied that garments made from a fabric or product falling into any one of the flammability classes will not be hazardous under some conditions.
Because of the sensitivity of fabrics to ambient atmospheric conditions, technique of specimen preparation, and inherent variability in the cloth itself, test results are not always closely reproducible either in the same laboratory or among several laboratories.
Finishes and fabric surface changes can exert a large effect on flammability. Therefore, fabrics are tested before as well as after one cycle of drycleaning followed by laundering.
This test method is not applicable to hats, gloves, footwear, or interlining fabrics.
1. Scope
1.1 This test method covers the evaluation of the flammability of textile fabrics as they reach the consumer for or from items other than children's sleepwear or protective clothing.
1.2 This test method measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or risk assessment of the materials, products, or assemblies under actual fire conditions.
1.3 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.
Note 1—This test method is not identical to 16 CFR Part 1610, Flammability of Clothing Textiles. Consumer Product Safety Commission regulations require that fabrics introduced into commerce meet the requirements of 16 CFR Part 1610.
1.4 The values stated in SI units are to be regarded as the standard; inch-pound units are provided for information only.
1.5 This test method does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this test method to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
 
2. Referenced Documents (purchase separately)
ASTM Standards
D123 Terminology Relating to Textiles
E176 Terminology of Fire Standards
ISO Standards
ISO13943 Fire safety
CPSC Guidance Document
16CFRPart1610 Standard for the Flammability of Clothing Textiles October 2008
Index Terms
apparel flammability; fabric flammability; Apparel fabrics; Career apparel fabrics; Flammability--textile fabrics/fibers;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025澳门正版资料大全官方版 | 香港今期开奖结果什么 | 香港最准最快资料免费下载安 | 香港今期开什么 | 2025香港马拉松 | 香港精准一肖一码 | 澳门六玄玄网论坛 | 港澳宝典最新版808001 | 49彩图库免费的资料港澳l | 2025年澳门天天彩开奖记录 | 香港2025内部精准资料大全 | 2025香港免费资料大全正式版 | 正宗版2025生肖卡表 | 2025新澳门原料免费大全 | 澳门精准四不像 | 2025年月19日澳门一肖一码准一肖 | 一肖一码100%中奖一 | 2025管家婆资料正版大全 | 2025新管家婆彩图今晚 | 四肖八码中特资料期期精选料 | 新澳好彩免费资料查询郢中白雪 | 今晚四不像必中一肖图118 | 2025年资料必中资料大全版单双 | 今晚澳门精准一肖一码 | 香港特马王 | 香港今晚六给彩开奖结果 | 49彩图库免费的资料港澳l | 二四六香港资料期期准千附三险阻 | 正版东方心经自动更新最新版下载 | 香港最准一肖100免费公开的信息 | 2025澳门全年资料大全免费下载 | 必中八码 | 494949cc澳门资料大全202 494949Cc澳门资料大全 | 2025年新澳门正版资料大全免费 | 2025年澳门大学内地招生简章 | 118彩色厍图库彩图下载119图 | 二四六香港免费资料玄机 | 澳门四肖八码期期准免费资料精选 | 2025澳门天天彩正版免费 | 澳门一码一肖一特一中 | 2025年资料大全app免费下载安装 |