ASTM D1389薄固體電絕緣材料的保護(hù)電壓試驗(yàn)用標(biāo)準(zhǔn)試驗(yàn)方法
ASTM D1389 Standard Test Method for Proof-Voltage Testing of Thin Solid Electrical Insulating Materials
ASTM D1389薄固體電絕緣材料的保護(hù)電壓試驗(yàn)用標(biāo)準(zhǔn)試驗(yàn)方法
Occasional dielectric defects may be found in commercially available and acceptable thin electric insulating materials. More often than not, these materials are used in multiple layers. The probability that occasional dielectric weak spots will coincide from layer to layer is very small but increases with the frequency of occurrence of these defects. The proof-voltage test serves to indicate the frequency of occurrence of dielectric defects and facilitates the isolation of areas where the defects are excessive.
Some uses of thin electrical insulating materials require the complete absence of any dielectric defects. The proof-voltage test serves to locate dielectric defects, making possible repair or replacement of the area involved as may be desirable.
In the absence of detected faults, this test method is nondestructive to the material being evaluated, except as discussed in 1.2 and 4.3.
A critical part of the apparatus and procedure is the sensitivity and speed of response of the fault detection device. The latter is usually a circuit breaker. Depending upon the characteristics of this latter component, it is very likely that the results obtained using different sets of apparatus will exhibit significant variability.
It is essential that the fault detector respond only to fault currents and that fault currents above a pre-defined value always result in a fault detector response. The design, adjustment, and operation of the apparatus must avoid both erroneous functioning and any erroneous nonfunctioning of the fault detector that might be the result of charging currents, imbalance of impedance, or component malfunction.
The proof-voltage test has been used as a manufacturing control test and as an acceptance test to guarantee a minimum level of dielectric defects.
If this test method is used as an acceptance test, take care that the factors discussed in 5.4 and 5.5 have been considered, and if more than one set of apparatus is to be used, that comparable results are obtained from them.
1. Scope
1.1 This test method covers a general procedure for proof-voltage testing of thin solid electrical insulating materials at commercial power frequencies. It is intended to apply principally to flat materials but is applicable, with modification, to any form that permits continuously passing the material between suitable electrodes. ,
1.2 On extremely thin materials (usually less than 0.05 mm (0.002 in.)), the test results may be influenced more by mechanical damage caused by conditions of test than by dielectric defects. Consequently, this test method is not recommended for use with extremely thin materials, unless prior determination has established that the test results are not influenced by mechanical damage.
1.3 While the equipment and procedures described in this test method relate specifically to tests made with power frequency ac voltages, similar equipment and procedures are used for proof-voltage tests using dc voltages. To the extent that it applies to dc tests, this test method can serve as a guide for persons making such tests. However, only tests made with power frequency ac voltages can be said to be in accordance with this test method.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
 
2. Referenced Documents (purchase separately)
ASTM Standards
D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
D1711 Terminology Relating to Electrical Insulation
Index Terms
proof-voltage testing; thin solid insulating materials;

  詳情請(qǐng)咨詢
  防火資源網(wǎng)-阻燃防火測(cè)試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測(cè)試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測(cè)試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁(yè) | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號(hào)
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號(hào):閩ICP備09009213號(hào)-1在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言
主站蜘蛛池模板: 澳门跑狗图2025年今晚 | 澳门彩资料大全集(中国)官方网站ios | 新澳门与香港正版精准免费资料大全 | 新澳门一肖一码精准资料公开 | 2025澳门正版资料2025新澳门六合精准资料 | 2025精准管家婆一肖一马 | 澳门最精准真正最精准龙门客栈 | 最准一肖一码准吗 | 澳门正版资料免费大全精 | 2025澳门天天开好彩精准24码 | 944cc资料免一费大全 | 澳彩资料大全查询与全面贯彻解释落实的研究 | 49图库资料中心免费v4 | 2025全年澳彩资料免费资料大全 | 香港澳门免费资料大全是一家为客户提供澳门正版资料免费大全公开 | 金光佛论坛一句一码 | 2025年新澳门和香港全年免费资料大全 | 三毛图库 | 新澳门资料大全免费安装 | 二四六天好彩944cc免费资料大全二四正版金牛网 | 2025澳彩大全资料免费 | 管家婆今期图今天更新 | 管家婆一码一肖资料大 | 49图库港澳台开奖记录 | 2025香港马会资枓大全免费 | 2025一句赢大钱资料一 | 2025年新奥开奖结果! | 澳门9944cc天下彩图文 | 黄大仙必中三码全年免费资料 | 红姐彩色统一图库官网版权威新闻 | 2025年香港资料精准 | 澳门精准的资料大全 | 澳门展出圆明园兽首铜像 | 49图库app手机下载安装app下载 | 新澳门资料大全正版资料?奥利 | 澳门正版免费全年资料大全旅游团 | 新澳好彩免费资料查询郢中白雪 | 2025一码一肖一特 | 118彩色厍图库彩图移动客户端下载 | 2025澳门精准正版免费021期47 | 澳码精准100%一肖一码最准肖 |