ASTM D149脲甲醛樹脂溶液中不揮發(fā)物含量的標(biāo)準(zhǔn)測試方法

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):279  分享到: 分享到騰訊微博
ASTM D149脲甲醛樹脂溶液中不揮發(fā)物含量的標(biāo)準(zhǔn)測試方法
ASTM D149 Standard Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
ASTM D149脲甲醛樹脂溶液中不揮發(fā)物含量的標(biāo)準(zhǔn)測試方法
The dielectric strength of an electrical insulating material is a property of interest for any application where an electrical field will be present. In many cases the dielectric strength of a material will be the determining factor in the design of the apparatus in which it is to be used.
Tests made as specified herein are suitable for use to provide part of the information needed for determining suitability of a material for a given application; and also, for detecting changes or deviations from normal characteristics resulting from processing variables, aging conditions, or other manufacturing or environmental situations. This test method is useful for process control, acceptance or research testing.
Results obtained by this test method can seldom be used directly to determine the dielectric behavior of a material in an actual application. In most cases it is necessary that these results be evaluated by comparison with results obtained from other functional tests or from tests on other materials, or both, in order to estimate their significance for a particular material.
Three methods for voltage application are specified in Section 12: Method A, Short-Time Test; Method B, Step-by-Step Test; and Method C, Slow Rate-of-Rise Test. Method A is the most commonly-used test for quality-control tests. However, the longer-time tests, Methods B and C, which usually will give lower test results, will potentially give more meaningful results when different materials are being compared with each other. If a test set with motor-driven voltage control is available, the slow rate-of-rise test is simpler and preferable to the step-by-step test. The results obtained from Methods B and C are comparable to each other.
Documents specifying the use of this test method shall also specify:
Method of voltage application,
Voltage rate-of-rise, if slow rate-of-rise method is specified,
Specimen selection, preparation, and conditioning,
Surrounding medium and temperature during test,
Electrodes,
Wherever possible, the failure criterion of the current-sensing element, and
Any desired deviations from the recommended procedures as given.
If any of the requirements listed in 5.5 are missing from the specifying document, then the recommendations for the several variables shall be followed.
Unless the items listed in 5.5 are specified, tests made with such inadequate reference to this test method are not in conformance with this test method. If the items listed in 5.5 are not closely controlled during the test, it is possible that the precisions stated in 15.2 and 15.3 will not be obtained.
Variations in the failure criteria (current setting and response time) of the current sensing element significantly affect the test results.
Appendix X1. contains a more complete discussion of the significance of dielectric strength tests.
1. Scope
1.1 This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. ,
1.2 Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem.
1.3 This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used (see 5.5).
1.4 It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium.
1.5 This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test.
1.6 This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method D3151).
1.7 This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). With the addition of instructions modifying Section 12, this test method is also suitable for use for proof testing.
1.8 This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial.
1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7. Also see 6.4.1.
 
2. Referenced Documents (purchase separately)
ASTM Standards
D374 Test Methods for Thickness of Solid Electrical Insulation
D618 Practice for Conditioning Plastics for Testing
D877 Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes
D1711 Terminology Relating to Electrical Insulation
D2413 Practice for Preparation of Insulating Paper and Board Impregnated with a Liquid Dielectric
D3151 Test Method for Thermal Failure of Solid Electrical Insulating Materials Under Electric Stress
D3487 Specification for Mineral Insulating Oil Used in Electrical Apparatus
D5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
IEC Standard
Pub.243-1 Methods of Test for Electrical Strength of Solid Insulating Materials--Part 1: Tests at Power Frequencies
ANSI Standard
C68.1 Techniques for Dielectric Tests, IEEE Standard No.
Index Terms
breakdown; breakdown voltage; calibration; criteria of breakdown; dielectric breakdown voltage; dielectric failure; dielectric strength; electrodes; flashover; power frequency; process-control testing; proof testing; quality-control testing; rapid rise; research testing; sampling; slow rate-of-rise; step-by-step; surrounding medium; voltage withstand; Commercial power frequencies; Dielectric breakdown voltage; Electrical properties; Power factor
 

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025澳门最准特马资料 | 49图库港澳台开奖结果今天最 | 澳门天天彩免费资料大全免费查询 | 今期澳门开奖结果查询 | 2025澳门开奖历史记录查询结果!欢迎网友一起浏览并收藏! | 六库宝典旧版go6h | 2025澳门必出一肖一码 | 彩库宝典下载安装官网手机版本 | 2025香港六合资料 | 澳门赤兔论坛 | 2025今晚特马开多少号 | 新澳门四肖期期准中特更新时间025期48 | 下载6合宝典彩库官网首页 下载626969网站1 | 澳门六开奖结果2025开奖记录查询 | 澳门正版资料大全免费 | 能看资料的六盒宝典下2025 | 澳门三肖 | 香港开码历史记录查询 | 2025年香港公司注册全流程详解 | 刘伯温四肖八码精准网期期免费开 | 今晚必出准确生肖 | 2025今晚澳门开奖号码 | 2025澳门正版免费资料大全 | 118免费彩色印刷图app下载 | 澳门期期准免费精准 | 2025澳门天天彩免费资料大全 | 正版查询首选平台 | 2025年澳门天天开好彩免费资科 | 2025新澳精准 | 2025正版资料大全完整版香港 | 管家婆一肖一码100澳门 | 管家婆精选三期内必开生肖 | 澳门管家婆免费资料的特点 | 2025年新奥门管家婆资料 | 正宗香港内部资料网站 | 管家婆一码一肖100准 | 新澳天天彩正版免费资料观看 | 管家婆免费| 2025澳门免费资格 | 澳门精准免费资料大全1 | 2025澳门天天六开好彩 |