NFPA 70E 車間電氣安全標準

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:1539  分享到: 分享到騰訊微博
NFPA 70E 車間電氣安全標準
NFPA 70E Standard for Electrical Safety in the Workplace®
NFPA 70E 車間電氣安全標準
 
90.2 Scope.
(A) Covered. This standard addresses electrical safety-related work practices for employee workplaces that are necessary for the practical safeguarding of employees relative to the hazards associated with electrical energy during activities such as the installation, inspection, operation, maintenance, and demolition of electric conductors, electric equipment, signaling and communications conductors and equipment, and raceways. This standard also includes safe work practices for employees performing other work activities that can expose them to electrical hazards as well as safe work practices for the following
(1) Installation of conductors and equipment that connect to the supply of electricity
(2) Installations used by the electric utility, such as office buildings, warehouses, garages, machine shops, and recreational buildings that are not an integral part of a generating plant, substation, or control center
(B) Not Covered. This standard does not cover safety-related work practices for the following
(1) Installations in ships, watercraft other than floating buildings, railway rolling stock, aircraft, or automotive vehicles other than mobile homes and recreational vehicles
(2) Installations underground in mines and self-propelled mobile surface mining machinery and its attendant electrical trailing cable
(3) Installations of railways for generation, transformation, transmission, or distribution of power used exclusively for operation of rolling stock or installations used exclusively for signaling and communications purposes
(4) Installations of communications equipment under the exclusive control of communications utilities located outdoors or in building spaces used exclusively for such installations
(5) Installations under the exclusive control of an electric utility where such installations
a. Consist of service drops or service laterals, and associated metering, or
b. Are located in legally established easements or rights-of-way designated by or recognized by public service commissions, utility commissions, or other regulatory agencies having jurisdiction for such installations, or
c. Are on property owned or leased by the electric utility for the purpose of communications, metering, generation, control, transformation, transmission, or distribution of electric energy, or
d. Are located by other written agreements either designated by or recognized by public service commissions, utility commission, or other regulatory agencies having jurisdiction for such installations. These written agreements shall be limited to installations for the purpose of communications, metering, generation, control, transformation, transmission, or distribution of electric energy where legally established easements or rights-of-way cannot be obtained.
These installations shall be limited to federal lands, Native American reservations through the U.S. Department of the Interior Bureau of Indian Affairs, military bases, lands controlled by port authorities and state agencies and departments, and lands owned by railroads.
 
 
Lives depend on you! Protect your personnel from electrical hazards and meet the highest standard for electrical safety with the 2012 edition of NFPA 70E®.
Workplace safety in the United States is evolving due to better awareness and implementation of NFPA 70E Standard for Electrical Safety in the Workplace®. Yet hundreds of deaths and thousands of disabling injuries still occur each year due to shock, electrocution, arc flash, and arc blast -- and most could be prevented through NFPA 70E compliance. The 2012 NFPA 70E responds to the challenges, making it easier to ensure an electrically safe working area and comply with OSHA 1910 Subpart S and OSHA 1926 Subpart K.
Get new ways to calculate risks and mitigate hazards.
Originally developed at OSHA's request, NFPA 70E responds to new information about the effects of arc flash, arc blast, and direct current (dc) hazards, and recent developments in electrical design and Personal Protective Equipment (PPE).
Coverage of direct current hazards is the first of its kind in the U.S.
The rising demand for alternative energy systems such as photovoltaic and wind power present greater dc shock and arc flash hazard exposures to workers. To protect personnel, NFPA 70E includes a new shock protection boundary, hazard/risk table, and incident energy calculation for direct current systems. Revised Article 320 focuses on safe work practices for stationary batteries and battery rooms, such as those used by alternative energy systems.
Make hazard/risk assessments and select proper PPE.
·    Revised requirements delineate the essential difference between "risk assessment" and "hazard identification." Supporting information is in revised Annex F.
·    Hazard/risk tables are expanded to include electrical system characteristics and arc-flash protection boundaries.
·    The 2* designation has been eliminated to clarify that all H/R Category 2 tasks require full-head PPE.
·    Change on "layering" for a combined arc-rating permits the use of arc-rated garments only.
·    Clarified text for arc flash hazard warning labels
Give your employees the know-how they need to be electrically safe on the job!
Training and audit-related revisions impact your company's electrical safety program. The 2012 NFPA 70E explains when the energized work permit (EWP) is required and what it should contain; requires emergency procedure instruction on AEDs (Automatic External Defibrillators), adds a new three-year maximum interval for employee training and documentation of content, and more. This edition also contains new information about implementing NFPA 70E within the framework of ANSI/AIHA Z10 and other health and safety management standards.
Order your copy of the new NFPA 70E, the Standard that's changing the way America works!
If you're responsible for ensuring workers are protected from shock and arc flash hazards, order NFPA 70E now to protect personnel and your reputation for safety. Contractors; risk managers; engineers; apartment, commercial, and retail building managers; and owners all have a stake in ending electrical-related accidents, liability, and loss. (Softbound, 103 pp., 2012)
 

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 4949澳门与香港今晚开什么 | 聚宝盆丽萍数据1183 | 全年资料大全2025 | 白小姐今晚特马期期准2025年一枕黄粱 | 新奥彩新澳2025年最新资料 | 2025澳门免费大全资料汇编 | 2025全年免费料大全 | 澳门精准一肖下载安装 | 香港2025内部精准资料大全 | 2025澳门天天六开好彩 | 三五图库app下载下载安装v8.8.2 三五图库app下载 | 7777788888王中王开奖十记录网一 | 三期必开一期三期必出特详情介绍 | 2025新澳一码一特 | 香港6合开奖结果开奖记录2025 | 2025香港图库免费资料大全看 | 管家婆2025正版资料图片大全 | 新澳天天彩免费资料大全查询 | 六库宝典go6h下载最新版 | 澳门特准一码中奖 | 2025香港港六开奖记录 | 澳彩资料免费的资料大全wwe | 2025年正版资料免费大全v5.6 | 澳门今晚必中一消 | 246天天好彩精选资料944 | 白小姐四必选一肖期期准 | 管家婆一码中奖王中王 | 2025澳门正版精准资料揭秘 | 管家婆三期必开一期 | 香港2025正版全年资料免费看 | 2025新奥精准资料免费 | 澳门一肖一码100精准2025 | 管家婆软件免费试用 | 香港精准资料大全 | 全香港最快最准的资料 | 2025香港特等特马资料全揭秘 | 49图库手机版 | 三元区人民政府关于印发三元区做大三产 | 2025年香港开奖结果记录等等 | 2025澳门资料库大全免费 | 2025年的特准特马资料 |