ASTM D2802電線及電纜用耐臭氧乙烯烴聚合物絕緣材料的標準規范

放大字體  縮小字體 發布日期:2012-02-10   瀏覽次數:260  分享到: 分享到騰訊微博
ASTM D2802電線及電纜用耐臭氧乙烯烴聚合物絕緣材料的標準規范
ASTM D2802 Standard Specification for Ozone-Resistant Ethylene-Alkene Polymer Insulation for Wire and Cable
ASTM D2802電線及電纜用耐臭氧乙烯烴聚合物絕緣材料的標準規范
This specification covers an ozone-resisting crosslinked rubber insulation compound for electrical wires and cables. The polymer shall consist substantially of ethylene-alkene copolymer (EAM) or ethylene-alkene diene terpolymer (EADM). This polymer type includes ethylenepropylene copolymer (EPM) and ethylenepropylene diene terpolymer (EPDM). The crosslinked insulation shall conform to the requirements for physical properties specified. Tests shall be performed in accordance to the following test methods: AC voltage withstand test; insulation resistance; DC voltage withstand tests; capacitance and dissipation factor; partial discharge level test; accelerated water absorption; and ozone resistance.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers an ozone-resisting crosslinked rubber insulation compound for electrical wires and cables. The polymer shall consist substantially of ethylene-alkene copolymer (EAM) or ethylene-alkene diene terpolymer (EADM). This polymer type includes ethylenepropylene copolymer (EPM) and ethylenepropylene diene terpolymer (EPDM).
1.2 This type of insulation is considered suitable for use on wire or cable which will be used in wet and dry locations with conductor temperatures up to 90°C during continuous operation, to 130°C during emergency overload conditions, and to 250°C during short-circuit conditions. It is considered suitable for all sizes and voltage classifications of single- and multiple-conductor power cables up to 35 000 V phase-to-phase at the 100 % insulation level and up to 25 000 V at the 133 % insulation level as listed in Table 1D, Conductor Sizes, Insulation Thicknesses, Test Voltages, and Corona Extinction Levels for Ethylene-Propylene Rubber Insulation, of Test Methods D470. Single-conductor cables shall have a supplementary covering over the insulation, and multiple-conductor cables shall have an overall covering.
1.3 Whenever two sets of values are presented, in different units, the values in the first set are the standard, while those in parentheses are for information only.
1.4 In many instances the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation and not to test the conductor or completed cable.

2. Referenced Documents (purchase separately)
ASTM Standards
D470 Test Methods for Crosslinked Insulations and Jackets for Wire and Cable
D1711 Terminology Relating to Electrical Insulation
ICEA Standard
T-24-380 Guide for Partial Discharge Procedure
Index Terms
AC voltage withstand test; accelerated water absorption; DC voltage withstand test; ethylene-propylene rubber; insulation resistance; ozone resisting; EPM/EPDM materials/applications--specifications; Ethylene-alkene polymer; Electrical insulating materials--specifications; Electrical insulating rubber--specifications; Insulated wire and cable--specifications ;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 开澳门开结果 | 澳门六开彩资料查询最新 | 香港资料大全正版资料2025年免费重拳出击 | 平码二中一哪个网站比较准 | 2025全年资料免费大全下载 | 澳门正版资料2025年大全下载 | 77778888精准管家婆免费 | 澳门与香港必开一肖一码一中 | 2025年新澳精准资料免费提供网站 | 香港今期开奖结果是什么 | 2025澳门天天开彩资料大全 | 澳门历史今晚开码记录 | 澳门四不像正版四不像揭秘 | 澳门三肖三码精准100% | 澳门今晚必中一肖一码准确 | 49图库本港澳台+开奖结果官方版下载 | 香港6合宝旧版下载安装 | 澳门2025资料大全 | 2025香港正版资料免费大全2025年 | 2025澳门正版精准 | 二四六天天彩资料大全网最新官网版 | 管家婆必出一肖一码 | 管家婆资料专区两波20码 | 2025年澳门一肖一码今晚准吗专注于材料测试 | 2025澳门六今晚开奖结果出来 | 49图库资料网站 | 2025新澳精准资料免费大全 | 2025澳门正版全年免费资料app | 现任国际奥委会主席 | 新澳门管家婆免费资料查询 | 澳门资料大全+正版资料2025年 | 新址246正版资料免费大全二四六 | 三五图库大全最新版下载 | 香港最快直播现场 | 澳门最快最准的资料免费手机 | 2025年新澳门今晚开奖结果2025年 | 2025澳门精准正版资料大全免费 | 白小姐三肖三码期期特期期中 | 澳门今晚开的是什么马 | 新澳门一肖必中 | 澳门最准七码中特 |