1.1 Scope.
1.1.1 This standard shall specify requirements for the design, performance, testing, and certification of nonprimary protective station/work uniforms and the individual garments comprising station/work uniforms.
1.1.2 This standard shall also specify requirements for the thermal stability of textiles used in the construction of station/work uniforms.
1.1.3 This standard shall also specify optional requirements for flame resistant textiles where such textiles are specified or claimed to be used in construction of station/work uniforms.
1.1.4 This standard shall not specify requirements for clothing that is intended to provide primary protection from given hazard exposures.
1.1.5* Certification of station/work uniforms to the requirements of this standard shall not preclude certification to additional applicable standards for primary protective clothing where the clothing meets all requirements of each standard.
A.1.1.5 Station/work uniforms that are certified as compliant only with NFPA 1975 are not primary protective garments and cannot be relied on to provide protection from specific hazards, such as those encountered during structural or wildland fire fighting. Other standards are written for garments that provide primary protection for specific hazards to which fire fighters can be exposed while participating in emergency operations or training. However, compliant station/work uniforms could also be certified to another standard for primary protective garments and thus be both a primary protective garment for the specific hazard that the other standard addresses and a station/work uniform that is compliant with NFPA 1975. Station/work uniforms that receive such dual certification (to NFPA 1975 and to a primary protective garment standard) would always exceed the minimum requirements of NFPA 1975. Examples of primary protective garment standards include, but are not limited to, NFPA 1951, Standard on Protective Ensembles for Technical Rescue Incidents; NFPA 1977, Standard on Protective Clothing and Equipment for Wildland Fire Fighting; NFPA 1994, Standard on Protective Ensembles for First Responders to CBRN Incidents; and NFPA 1999, Standard on Protective Clothing for Emergency Medical Operations.
1.1.6 This standard shall not be construed as addressing all of the safety concerns associated with the use of compliant station/work uniform garments for their personnel. It shall be the responsibility of the persons and organizations that use compliant station/work uniform garments to establish safety and health practices and determine the applicability of regulatory limitations prior to use.
1.1.7 This standard shall not be construed as addressing all of the safety concerns, if any, associated with the use of this standard by testing facilities. It shall be the responsibility of the persons and organizations that use this standard to conduct testing of station/work uniform garments to establish safety and health practices and determine the applicability of regulatory limitations prior to using this standard for any designing, manufacturing, and testing.
1.1.8* This standard shall not specify requirements for any accessories that could be attached to the certified product but are not necessary for the certified product to meet the requirements of this standard.
A.1.1.8 Emergency response organizations are cautioned that accessories are not a part of the certified product but could be attached to the certified product by a means not engineered, manufactured, or authorized by the manufacturer. Emergency response organizations are cautioned that if the accessory or its means of attachment causes the structural integrity of the certified product to be compromised, the certified product might not comply with the standard for which it was designed, manufactured, and marketed. Additionally, if the accessory or its attachment means are not designed and manufactured from materials suitable for the hazardous environments of emergency incidents, the failure of the accessory or its attachment means could cause injury to the emergency responder. Because the aftermarket for certified product accessories is so broad, fire and emergency response organizations are advised to contact both the manufacturer of the accessory and the manufacturer of the certified product and verify that the accessory and its means of attachment are suitable for use in the intended emergency response environment. Emergency response organizations should seek and receive written documentation from both the accessory manufacturer and the manufacturer of the certified product to validate the following information
(1) The accessory for a certified product, and its attachment method, will not degrade the designed protection or performance of the certified product below the requirements of the product standard to which it was designed, manufactured, tested, and certified.
(2) The accessory, when properly attached to the certified product, shall not interfere with the operation or function of the certified product, or with the operation or function of any of the certified product’s component parts. Users are also cautioned that the means of attachment of the accessory that fail to safely and securely attach the accessory to the certified product can cause the accessory to be inadvertently dislodged from the certified product and create a risk to the wearer or other personnel in the vicinity.
1.1.9 Nothing herein shall restrict any jurisdiction or manufacturer from exceeding these minimum requirements.
 
 
Protect fire service and emergency services personnel from occupational hazards with thermally stable textiles that comply with the 2009 edition of NFPA 1975.
Increase on-the-job safety for emergency services personnel by complying with the 2009 NFPA 1975 Standard on Station/Work Uniforms for Emergency Services. This vital Standard specifies the latest requirements for the design, performance, testing, and certification of station/work uniforms constructed from thermally stable materials or flame resistant materials so that they will not cause or contribute to burn injury severity. Station/work uniforms are non-primary protective garments configured as long or short sleeve shirts (regular, tee, polo, sweatshirt), and pants and shorts; but do not include underwear, socks, dress uniforms, and outerwear.
Changes in the 2009 edition include
·    Updated certification provisions
·    Clarification of product labeling requirements
·    Revised "pass or fail" criteria for thermal stability
·    Changes in the criteria for commercial dry-cleaning procedure to test flame resistance
·    Updated Annex material
·    Clarifications and revisions to terminology for improved consistency and specificity
(Softbound, 24 pp., 2009)

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025今晚澳门 | 今晚澳门必中一肖一码 | 澳门璀璨烟花填满夜空 | 2025澳门论坛六肖六码精选 | 管家婆2025正版资料大全下载 | 最准一肖一码100中特 | 彩库宝典安全下载安装 | 澳门神算子高手论坛免费精准 | 天中图库陈华独胆预测 | 澳门今晚一肖码10o准管家娶 | 香港免费大全资料大全 | 华彩 | 2025年正版资料免费大全公开 | 曾道正版资料免费大全官方网 | 水果奶奶官方版免费下载[水果奶奶合集] | 六台宝典图库跑狗图 | 2025年香港人才市场展望与薪酬指南报告 | 内部传真澳门传真金光佛 | 怎么找不到老版的彩库宝典了 | 澳门三肖三码期期准免费资料 | 118图库手机版下载v1.0 | 118彩图库主图手机下载 | 新澳门免费资料大全 | 2025六和合彩开奖结果 | 今晚一码一肖免费公开 | 今天香港开什么特马 | 澳门开奖的历史资料合集 | 港澳宝典大全免费资料 | 香港彩库宝典手机苹果版 | 今晚澳门彩开什么码 | 新澳门2025年正版免费公开019期28 | 2025全年资料大全正 | 澳门精选免费资料大全家 | 管家婆(中国)官方网站ios | 香港6合宝典正版下载 | 新澳资彩长期免费资料 | 2025年澳门一肖一特一码一中—— | 今天澳门今晚马出什么 | 刘伯温说2025年怎么样 | 2025澳门六彩聚宝盆 | 新澳门2025摇号记录表查询 |