ASTM D5424電纜或光纜中絕緣材料在立式電纜槽結構中燃燒時的煙霧遮蔽性標準試驗方法

放大字體  縮小字體 發布日期:2012-02-07   瀏覽次數:150  分享到: 分享到騰訊微博
ASTM D5424電纜或光纜中絕緣材料在立式電纜槽結構中燃燒時的煙霧遮蔽性標準試驗方法
ASTM D5424 Standard Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
ASTM D5424電纜或光纜中絕緣材料在立式電纜槽結構中燃燒時的煙霧遮蔽性標準試驗方法

This test method provides a means to measure a variety of fire-test-response characteristics associated with smoke obscuration and resulting from burning the electrical insulating materials contained in electrical or optical fiber cables. The specimens are allowed to burn freely under well ventilated conditions after ignition by means of a propane gas burner.
Smoke obscuration quantifies the visibility in fires.
This test method is also suitable for measuring the rate of heat release as an optional measurement. The rate of heat release often serves as an indication of the intensity of the fire generated.
Other optional fire-test-response characteristics that are measurable by this test method are useful to make decisions on fire safety. The most important gaseous components of smoke are the carbon oxides, present in all fires. They are major indicators of the toxicity of the atmosphere and of the completeness of combustion and are often used as part of fire hazard assessment calculations and to improve the accuracy of heat release measurements. Other toxic gases, which are specific to certain materials, are less crucial for determining combustion completeness.
Test Limitations:
The fire-test-response characteristics measured in this test method are a representation of the manner in which the specimens tested behave under certain specific conditions. Do not assume they are representative of a generic fire performance of the materials tested when made into cables of the construction under consideration.
In particular, it is unlikely that this test method is an adequate representation of the fire behavior of cables in confined spaces, without abundant circulation of air.
This is an intermediate-scale test, and the predictability of its results to large scale fires has not been determined. Some information exists to suggest that it has been validated against some large-scale scenarios.
1. Scope
1.1 This is a fire-test-response standard.
1.2 This test method provides a means to measure the smoke obscuration resulting from burning electrical insulating materials contained in electrical or optical fiber cables when the cable specimens, excluding accessories, are subjected to a specified flaming ignition source and burn freely under well ventilated conditions.
1.3 This test method provides two different protocols for exposing the materials, when made into cable specimens, to an ignition source (approximately 20 kW), for a 20 min test duration. Use it to determine the flame propagation and smoke release characteristics of the materials contained in single and multiconductor electrical or optical fiber cables designed for use in cable trays.
1.4 This test method does not provide information on the fire performance of electrical or optical fiber cables in fire conditions other than the ones specifically used in this test method nor does it measure the contribution of the cables to a developing fire condition.
1.5 Data describing the burning behavior from ignition to the end of the test are obtained.
1.6 The production of light obscuring smoke is measured.
1.7 The burning behavior is documented visually, by photographic or video recordings, or both.
1.8 The test equipment is suitable for making other, optional, measurements, including the rate of heat release of the burning specimen, by an oxygen consumption technique and weight loss.
1.9 Another set of optional measurements are the concentrations of certain toxic gas species in the combustion gases.
1.10 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. (See )
1.11 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.
1.12 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.
1.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
D1711 Terminology Relating to Electrical Insulation
E84 Test Method for Surface Burning Characteristics of Building Materials
E176 Terminology of Fire Standards
E800 Guide for Measurement of Gases Present or Generated During Fires
E1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
Underwriters Laboratories Standards
UL1685 Standard Vertical Tray Fire Propagation and Smoke Release Test for Electrical and Optical Fiber Cables, Underwriters Laboratories, Inc., January 27, 1992
Canadian Standards Association Standards
CSAStandardFT-4 Vertical Flame Tests: Cables in Cable Trays, Section 4.11.4 in C22.2 No. 0.3-M1985, Test Methods for Electrical Wires and Cables
IEEE Standards
IEEE1202 Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies, May 29, 1991.
Other Standards
ISO13943 Fire Safety-Vocabulary
NFPA Standard
ANSI/NFPA70-1990 National Electrical Code--1990, National Fire Protection Association
Index Terms
cable; cable tray; carbon dioxide; carbon monoxide; char; electrical cable; fire; fire-test response; flame; heat release; heat release rate; ignition; optical density; optical fiber cable; oxygen consumption calorimetry; smoke obscuration; smoke release; smoke release rate; total smoke released; toxic gases; Burning cables; Cables; Calorimeter; Carbon dioxide; Carbon monoxide (CO); Electrical shielding cable; Exhaust system design; Fire testing--electrical insulating materials; Flow and flow rate--insulations; Heat release; Ignition--electrical insulating materials; Instrumentation; Optical fiber/cable/conduit; Oxygen consumption; Smoke analysis; Smoke obscuration; Total smoke released; Toxic gases;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025年全年资料八百图库 | 2025澳门正版全年资料下载 | 白小姐今晚天什么特马 | 今晚澳门一码一肖百分百 | 香港正版资料大全免费歇后语 | 今晚的四不像图免费最新更新与数据下载 | 2025王中王资料大全公开 | 管家婆一肖一码取准确比必 | 白小姐必中一肖一码今晚 | 白小姐一码一肖 | 2025澳门正版资料全年免费公开官方版 | 港澳商务签新政:停留时间延长至14天 | 2025澳门资料大全正版资料 | 管家婆精准期期选一肖管家婆3期必 | 澳门马会传真内部绝密信封资料 | 一级高手独善其身六组三中三 | 澳门最快最准资料免费手机网站 | 2025新奥门管家婆正板资免费 | 澳门最准最新免费资料内部(2025已更新 | 246天天好彩免费资料最新版v.6 | 看今晚的四不像图正版什么 | 香港2025宝典正版资料库 | 新奥资料免费精准期期准和网络宽带发展的要求组建而成的集研发 | 2025澳彩今晚开什么号码 | 澳门管家婆资料正版大全 | 红姐彩色统一图库hi948免费手机 | 管家婆一码一肖100准全面释义解释落实 | 49彩票图库港澳台新版本下载 | 今晚必中一码一肖澳门 | 澳门最精准正最精准龙门客 | 澳门精准全年免费资料 | 新澳门最新开奖记录大全三五图库 | 2025年澳门正版资料 | 49图库澳门资料大全下载 | 澳门天天彩期期精准 | 2025年香港6合宝典二四六 | 澳门四肖八码期期准免费公 | 新澳门开奖结果2025开奖记录提供强大的专业招标采购信息查询和相关服务 | 管家婆最准一肖一码一中特 | 澳门开马 | 四柱预测图库 |