ASTM E1462光電器件模塊的完整性絕緣和連續(xù)地面路徑的標(biāo)準(zhǔn)試驗(yàn)方法
ASTM E1462  Standard Test Methods for Insulation Integrity and Ground Path Continuity of Photovoltaic Modules
ASTM E1462光電器件模塊的完整性絕緣和連續(xù)地面路徑的標(biāo)準(zhǔn)試驗(yàn)方法
The design of a photovoltaic module or system intended to provide safe conversion of the sun’radiant energy into useful electricity must take into consideration the possibility of hazard should the user come into contact with the electrical potential of the module. These test methods describe procedures for verifying that the design and construction of the module or system are capable of providing protection from shock through normal installation and use. At no location on the module should this electrical potential be accessible, with the obvious exception of the intended output leads.
These test methods describe procedures for determining the ability of the module to provide protection from electrical hazards.
These procedures may be specified as part of a series of qualification tests involving environmental exposure, mechanical stress, electrical overload, or accelerated life testing.
These procedures are normally intended for use on dry modules; however, the test modules may be either wet or dry, as indicated by the appropriate protocol.
These procedures may be used to verify module assembly on a production line.
Insulation resistance and leakage current are strong functions of module dimensions, ambient relative humidity and absorbed water vapor, and the ground path continuity procedure is strongly affected by the location of contacts and test leads to the module frame and grounding points.
5.6.1 For these reasons, it is the responsibility of the user of these test methods to specify the maximum acceptable leakage current for the dielectric voltage withstand test, and the maximum acceptable resistance for the ground path continuity procedure.
5.6.2 Fifty μA has been commonly used as the maximum acceptable leakage current (see ANSI/UL 1703, Section 26.1), and 0.1 Ω has been commonly used as the maximum acceptable resistance.
Some module designs may not use any external metallic components and thus lack a ground point designated by the module manufacturer. In these cases, the ground path continuity test is not applicable.
1. Scope
1.1 These test methods cover procedures for (1) testing for current leakage between the electrical circuit of a photovoltaic module and its external components while a user-specified voltage is applied and (2) for testing for possible module insulation breakdown (dielectric voltage withstand test).
1.2 A procedure is described for measuring the insulation resistance between the electrical circuit of a photovoltaic module and its external components (insulation resistance test).
1.3 A procedure is provided for verifying that electrical continuity exists between the exposed external conductive surfaces of the module, such as the frame, structural members, or edge closures, and its grounding point (ground path continuity test).
1.4 This test method does not establish pass or fail levels. The determination of acceptable or unacceptable results is beyond the scope of this test method.
1.5 There is no similar or equivalent ISO standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
E772 Terminology Relating to Solar Energy Conversion
E1328 Terminology Relating to Photovoltaic Solar Energy Conversion
Underwriters Laboratories Standard
ANSI/UL1703 Standard for Safety for Flat-Plate Photovoltaic Modules and Panels
Index Terms
dielectric voltage withstand; electrical testing; ground path continuity; insulation integrity; insulation resistance; modules; photovoltaics; solar energy;

  詳情請(qǐng)咨詢
  防火資源網(wǎng)-阻燃防火測(cè)試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測(cè)試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測(cè)試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁(yè) | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號(hào)
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號(hào):閩ICP備09009213號(hào)-1在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言
主站蜘蛛池模板: 香港正版资料大全年免费公开 | 一码黄大仙一肖一码37B | 118图库软件下载 | 醉红颜综合资料大全 | 4949中奖免费资料资料澳门与香港 | 管家婆手机版下载2025安卓最新版 | 澳门今晚开什么码 | 澳门管家一肖一码一开 | 澳门管家婆一肖一吗一中一特 | 118红姐护民图库开奖结果 | 2025管家婆资料正版大全 | 最准一码一肖100%精准老钱庄 | 香港内部最准马料 | 新澳门资料大全免费新鼬 | 2025买马生肖号码表 | 澳门精准四不像下载 | 2025年1一154期资料 | 花儿绽放总决赛暨颁奖盛典播出 | 49tk图库港澳2025客户端下载 | 老版的彩库宝典网址 | 管家婆软件| 2025年澳门今天晚上开什么号码 | 2025澳门正版资料免费资料大全 | 神算子天机资料论坛 | 2025年澳门今晚开奖结果 | 澳门最准一肖一码一码孑准确资料解释落实 | 澳门2025今晚揭晓哪号码 | 六库宝典旧版go6h | 香港今期开奖结果号码 | 王中王493333www| 澳门必中一肖一码精准 | 今期必中四不像图今晚 | 管家婆精准三肖必中一期 | 三码中一码精准 | 2025新奥资料免费精准资料 | 新澳彩正版资料免费大全精准 | 今晚一定出准确生肖 | 天空彩资料大全二四六天天下载 | 澳门六开彩开奖结果开奖记录 | 澳门正版资料免费大全 | 香港正版资料大全下载 |