ASTM E1529測(cè)定大型烴類物資貯存庫(kù)燃燒對(duì)結(jié)構(gòu)構(gòu)件和組件的影響的標(biāo)準(zhǔn)試驗(yàn)方法

放大字體  縮小字體 發(fā)布日期:2012-02-08   瀏覽次數(shù):54  分享到: 分享到騰訊微博
ASTM E1529測(cè)定大型烴類物資貯存庫(kù)燃燒對(duì)結(jié)構(gòu)構(gòu)件和組件的影響的標(biāo)準(zhǔn)試驗(yàn)方法
ASTM E1529  Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and Assemblies
ASTM E1529測(cè)定大型烴類物資貯存庫(kù)燃燒對(duì)結(jié)構(gòu)構(gòu)件和組件的影響的標(biāo)準(zhǔn)試驗(yàn)方法
These test methods are intended to provide a basis for evaluating the time period during which a beam, girder, column, or similar structural assembly, or a nonbearing wall, will continue to perform its intended function when subjected to a controlled, standardized fire exposure.
In particular, the selected standard exposure condition simulates the condition of total continuous engulfment of a member or assembly in the luminous flame (fire plume) area of a large free-burning-fluid-hydrocarbon pool fire. The standard fire exposure is basically defined in terms of the total flux incident on the test specimen together with appropriate temperature conditions. Quantitative measurements of the thermal exposure (total heat flux) are required during both furnace calibration and actual testing.
It is recognized that the thermodynamic properties of free-burning, hydrocarbon fluid pool fires have not been completely characterized and are variable depending on the size of the fire, the fuel, environmental factors (such as wind conditions), the physical relationship of the structural member to the exposing fire, and other factors. As a result, the exposure specified in these test methods is not necessarily representative of all the conditions that exist in large hydrocarbon pool fires. The specified standard exposure is based upon the best available information and testing technology. It provides a basis for comparing the relative performance of different assemblies under controlled conditions.
Any variation to construction or conditions (that is, size, method of assembly, and materials) from that of the tested assembly is capable of substantially changing the performance characteristics of the assembly.
Separate procedures are specified for testing column specimens with and without an applied superimposed load.
The procedures for testing loaded columns stipulate that the load shall be applied axially. The applied load is to be the maximum load condition allowed under nationally recognized structural design criteria unless limited design criteria are specified and a corresponding reduced load applied.
The procedure for testing unloaded steel column specimens includes temperature limits. These limits are intended to define the temperature above which a steel column with an axially applied design allowable load would fail structurally.
Note 1—The procedure for unloaded specimens also provides for the testing of other than steel columns provided that appropriate acceptance criteria have been established.
Separate procedures are also specified for testing beam assemblies with and without an applied superimposed load.
The procedure for testing loaded specimens stipulates that the beam shall be simply supported. Application of restraint against longitudinal thermal expansion depends on the intended use, as specified by the customer. The applied load is intended to be the allowable design load permitted for the beam as determined in accordance with accepted engineering practice.
The procedure for testing unloaded beams includes temperature limits for steel. These limits are to define the temperature above which a simply supported, unrestrained beam would fail structurally if subjected to the allowable design load. The procedure for unloaded specimens also provides for the testing of other than steel and reinforced concrete beams provided that appropriate acceptance criteria have been established.
It is recognized that beam assemblies that are tested without load will not deflect to the same extent as an identical assembly tested with load. As a result, tests conducted in accordance with the unloaded beam procedure are not intended to reflect the effects of crack formation, dislodgement of applied fire protection materials, and other factors that are influenced by the deflection of the assembly.
A separate procedure is specified for testing the fire-containment capability of a wall/bulkhead/partition, etc. Acceptance criteria include temperature rise of nonfire exposed surface, plus the ability of the wall to prohibit passage of flames or hot gases, or both.
In most cases, the structural assemblies that will be evaluated in accordance with these test methods will be located outdoors and subjected to varying weather conditions that are capable of adversely affecting the fire endurance of the assembly. A program of accelerated weathering followed by fire exposure is described to simulate such exposure.
These test methods provide for quantitative heat flux measurements to support the development of design fires and the use of fire safety engineering models to predict thermal exposure and material performance in a wide range of fire scenarios.
1. Scope
1.1 The test methods described in this fire-test-response standard are used for determining the fire-test response of columns, girders, beams or similar structural members, and fire-containment walls, of either homogeneous or composite construction, that are employed in HPI or other facilities subject to large hydrocarbon pool fires.
1.2 It is the intent that tests conducted in accordance with these test methods will indicate whether structural members of assemblies, or fire-containment wall assemblies, will continue to perform their intended function during the period of fire exposure. These tests shall not be construed as having determined suitability for use after fire exposure.
1.3 These test methods prescribe a standard fire exposure for comparing the relative performance of different structural and fire-containment wall assemblies under controlled laboratory conditions. The application of these test results to predict the performance of actual assemblies when exposed to large pool fires requires a careful engineering evaluation.
1.4 These test methods provide for quantitative heat flux measurements during both the control calibration and the actual test. These heat flux measurements are being made to support the development of design fires and the use of fire safety engineering models to predict thermal exposure and material performance in a wide range of fire scenarios.
1.5 These test methods are useful for testing other items such as piping, electrical circuits in conduit, floors or decks, and cable trays. Testing of these types of items requires development of appropriate specimen details and end-point or failure criteria. Such failure criteria and test specimen descriptions are not provided in these test methods.
1.6 Limitations—These test methods do not provide the following:
1.6.1 Full information on the performance of assemblies constructed with components or of dimensions other than those tested.
1.6.2 An evaluation of the degree to which the assembly contributes to the fire hazard through the generation of smoke, toxic gases, or other products of combustion.
1.6.3 Simulation of fire behavior of joints or connections between structural elements such as beam-to-column connections.
1.6.4 Measurement of flame spread over the surface of the test assembly.
1.6.5 Procedures for measuring the test performance of other structural shapes (such as vessel skirts), equipment (such as electrical cables, motor-operated valves, etc.), or items subject to large hydrocarbon pool fires, other than those described in 1.1.
1.6.6 The erosive effect that the velocities or turbulence, or both, generated in large pool fires has on some fire protection materials.
1.6.7 Full information on the performance of assemblies at times less than 5 min because the rise time called out in Section 5 is longer than that of a real fire.
1.7 These test methods do not preclude the use of a real fire or any other method of evaluating the performance of structural members and assemblies in simulated fire conditions. Any test method that is demonstrated to comply with Section 5 is acceptable.
1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.9 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.11 The text of this standard references notes and footnotes which provide explanatory information. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

2. Referenced Documents (purchase separately)
ASTM Standards
B117 Practice for Operating Salt Spray (Fog) Apparatus
D822 Practice for Filtered Open-Flame Carbon-Arc Exposures of Paint and Related Coatings
E119 Test Methods for Fire Tests of Building Construction and Materials
E176 Terminology of Fire Standards
E457 Test Method for Measuring Heat-Transfer Rate Using a Thermal Capacitance (Slug) Calorimeter
E459 Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter
E511 Test Method for Measuring Heat Flux Using a Copper-Constantan Circular Foil, Heat-Flux Transducer
E814 Test Method for Fire Tests of Penetration Firestop Systems
E2683 Test Method for Measuring Heat Flux Using Flush-Mounted Insert Temperature-Gradient Gages
Code of Federal Regulations
46 CFR 164.007 Structural Insulations
IMO Documents
IMOA754
ISO Standard
ISO834-1 Fire Resistance Tests - Elements of Building Construction - Part 1: General Requirements
Index Terms
fire test response; hydrocarbon pool fire; heat flux; temperature; thermal exposure; thermal shock; Beam test; Column tests; Fire-resistant materials/testing; Fire testing--building materials; Fire-test response; Fluid-hydrocarbon-fueled pool fires; Heat flux; Hydrocarbon pool fire; Hydrocarbon processing industry (HPI); Large hydrocarbon pool fire; Structural building materials/applications; Temperature tests--building materials; Thermal shock materials/testing; Walls;


  詳情請(qǐng)咨詢
  防火資源網(wǎng)-阻燃防火測(cè)試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測(cè)試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測(cè)試
推薦圖文
點(diǎn)擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號(hào)
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號(hào):閩ICP備09009213號(hào)-1在線客服 點(diǎn)擊QQ交談/留言 點(diǎn)擊QQ交談/留言
主站蜘蛛池模板: 今晚澳门一肖一码必中6149 | 2025资料大全 | 2025年澳门必中一肖一码 | 水果奶奶一码一肖手机论坛 | 澳门100%五码中特十码中特 | 澳门四肖四马中特期期准 | 2025澳门码开奖记录 | 新奥天天全年免费大全 | 2025全年新澳门与香港正版免费资料大全 | 六台宝典资料 | 香港资料大全正版资料使用方法 | 管家婆一码一肖资料 | 新澳最新最快资料 | 正版管家正版管家家婆 | 澳门正版资料大全免费官方版 | 澳门六开彩免费资料大全百度 | 澳门2025年的资料 | 一肖一码免费公开中特ytwiwi | 2025年香港免费资料大全正版2025 | 澳门香港资料大全网为您提供免费全国彩票开奖结果查询 | 最准一码一肖100%精准965 | 澳门六下彩资料在线看 | 澳门玄武版心水版图标最新资讯 | 老澳门六开彩资料查询最新 | 2025香港正版全年免费资料最新版 | 香港免费公开资料 | 四不像正版+正版四不像图片 | 2025香港最新开奖结果查询 | 澳门挂牌正版挂牌之全篇必备攻略 | 澳门六开彩天天免费资料大全正版 | 2025澳门金光佛 | 澳门内部资料 | 49图库全新版本港澳台 | 钱多多论坛的网址 | 澳媒:美为何不愿承认中国经济实力 | 2025今晚新澳门开奖 | 白小姐一码中持期期准 | 香港35图库印刷大全 | 新澳门内部资料精准大全 | 澳门正版资料大全资料 | 香港精准资料大全 |