ASTM D5537 Standard Test Method for Heat Release, Flame Spread, Smoke Obscuration, and Mass Loss Testing of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
ASTM D5537電纜或光纜絕緣材料在立式電纜槽裝置中燃燒時(shí)熱發(fā)散,火焰?zhèn)鞑?/font>,煙的昏暗度和質(zhì)量損失測(cè)試的標(biāo)準(zhǔn)試驗(yàn)方法

This test method provides a means to measure a variety of fire-test-response characteristics associated with heat and smoke release and resulting from burning the materials insulating electrical or optical fiber cables, when made into cables and installed on a vertical cable tray. The specimens are allowed to burn freely under well ventilated conditions after ignition by means of a propane gas burner.
The rate of heat release often serves as an indication of the intensity of the fire generated. General considerations of the importance of heat release rate are discussed in Appendix X1 and considerations for heat release calculations are in Appendix X2.
Other fire-test-response characteristics that are measurable by this test method are useful to make decisions on fire safety. The test method is also used for measuring smoke obscuration. The apparatus described here is also useful to measure gaseous components of smoke; the most important gaseous components of smoke are the carbon oxides, present in all fires. The carbon oxides are major indicators of the completeness of combustion and are often used as part of fire hazard assessment calculations and to improve the accuracy of heat release measurements.
Test Limitations:
The fire-test-response characteristics measured in this test are a representation of the manner in which the specimens tested behave under certain specific conditions. Do not assume they are representative of a generic fire performance of the materials tested when made into cables of the construction under consideration.
In particular, it is unlikely that this test is an adequate representation of the fire behavior of cables in confined spaces, without abundant circulation of air.
This is an intermediate-scale test, and the predictability of its results to large scale fires has not been determined. Some information exists to suggest validation with regard to some large-scale scenarios.
1. Scope
1.1 This is a fire-test-response standard.
1.2 This test method provides a means to measure the heat released and smoke obscuration by burning the electrical insulating materials contained in electrical or optical fiber cables when the cable specimens, excluding accessories, are subjected to a specified flaming ignition source and burn freely under well ventilated conditions. Flame propagation cable damage, by char length, and mass loss are also measured.
1.3 This test method provides two different protocols for exposing the materials, when made into cable specimens, to an ignition source (approximately 20 kW), for a 20 min test duration. Use it to determine the heat release, smoke release, flame propagation and mass loss characteristics of the materials contained in single and multiconductor electrical or optical fiber cables.
1.4 This test method does not provide information on the fire performance of materials insulating electrical or optical fiber cables in fire conditions other than the ones specifically used in this test method nor does it measure the contribution of the materials in those cables to a developing fire condition.
1.5 Data describing the burning behavior from ignition to the end of the test are obtained.
1.6 This test equipment is suitable for measuring the concentrations of certain toxic gas species in the combustion gases (see Appendix X4).
1.7 The values stated in SI units are to be regarded as standard (see ). The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.
1.8 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions..
1.9 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.
1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
D1711 Terminology Relating to Electrical Insulation
D5424 Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
E84 Test Method for Surface Burning Characteristics of Building Materials
E176 Terminology of Fire Standards
E603 Guide for Room Fire Experiments
E800 Guide for Measurement of Gases Present or Generated During Fires
E1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
E1537 Test Method for Fire Testing of Upholstered Furniture
E2067 Practice for Full-Scale Oxygen Consumption Calorimetry Fire Tests
NFPA Standards
NFPA286 Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
Underwriters Laboratories Standards
UL1685 Standard Vertical Tray Fire Propagation and Smoke Release Test for Electrical and Optical Fiber Cables
Canadian Standards Association Standard
CSAFT4,VerticalFlame No. 0.3, Test Methods for Electrical Wires and Cables
IEEE Standard
IEEE1202 Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies
ISO Standard
ISO13943 Fire Safety--Vocabulary
Index Terms
cable; cable tray; calorimetry; carbon dioxide; carbon monoxide; char; electrical cable; electrical insulation; fire; fire-test response; flame; heat release; heat release rate; ignition; optical density; optical fiber cable; oxygen consumption calorimetry; smoke obscuration; smoke release; toxic gases; Cables; Char; Electrical insulating solids; Electrical shielding cable; Fire testing--electrical insulating materials; Fire-test response; Flame heat release; Heat release; Mass flow; Mass loss testing; Optical fiber/cable/conduit; Oxygen consumption calorimetry; Smoke obscuration; Symbols; Vertical cable tray configuration; Volumetric measurement

  詳情請(qǐng)咨詢
  防火資源網(wǎng)-阻燃防火測(cè)試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測(cè)試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
 
主站蜘蛛池模板: 正版管家婆图片2025年澳门146期 | 2025澳门今晚开特马开 | 2025澳门精准正版资料汇总 | 白小姐一码中特期期准最新版下载 | 平码精准三中三免费论坛 | 2025澳门天天开好彩大全4 | 管家婆一肖一码100%准资料大全 | 新奥彩2025年免费资料查询 | 7777788888精准新传真设计制作 | 六盒宝典开奖结果今晚 | 赛马论坛| 2025年正版资料免费大全 | 二四六天天好彩(944CC)二四六天天好彩图 | 免费澳门一肖一码100%准确 | 2025澳门精准正版免费官网版 | 今晚开什么特马2025年3 | 2025澳门免费资料大全100% | 澳门内部资料精准公开 | 2025澳门正版资料免费大全官方网站入口 | 626969澳彩资料大全2025年新 | 今晚的开奖是否沿袭过去 | 澳门精准正版资料免费大全官方版下载 | 2025澳门本期开什么号 | 澳门精准免费资料大全u7 | 新澳门今晚开特马结果查询 | 天下彩 9944CC 天下 | 澳门今晚一码肖100准管家妹 | 赤兔版六给彩澳门 | 澳门开奖直播在线观看 | 澳门六开彩资料免费大全 | 118彩色厍图印刷手机下载 | 海通证券大智慧2025 | 四不像图片今晚必中2025 | 2025年澳门内部资料软件官方正式 | 2025澳门国际幻彩大巡游 | 今期香港老饱狗玄机图 | 四肖八码期期准精选资料丿免费版下载 | 2025澳门彩免费资料大全 | 澳彩资料真的准 | 香港今晚六给彩开奖结果 | 三五图库大全下载安装v2.3.2 |