ASTM D6113用錐形量熱計對電纜或光纜中絕緣材料的著火試驗反應特性測定的標準試驗方法

放大字體  縮小字體 發布日期:2012-02-08   瀏覽次數:129  分享到: 分享到騰訊微博
ASTM D6113用錐形量熱計對電纜或光纜中絕緣材料的著火試驗反應特性測定的標準試驗方法
ASTM D6113 Standard Test Method for Using a Cone Calorimeter to Determine Fire-Test-Response Characteristics of Insulating Materials Contained in Electrical or Optical Fiber Cables
ASTM D6113用錐形量熱計對電纜或光纜中絕緣材料的著火試驗反應特性測定的標準試驗方法

This test method is used to determine the heat release rate and a number of other fire-test-response characteristics as a result of exposing insulating materials contained in electrical or optical cables to a prescribed heating flux in the cone calorimeter apparatus.
Quantitative heat release measurements provide information that is potentially useful for design of electrical or optical cables, and product development.
Heat release measurements provide useful information for product development by giving a quantitative measure of specific changes in fire performance caused by component and composite modifications. Heat release data from this test method will not be predictive of product behavior if the product will not spread flame over its surface under the fire exposure conditions of interest.
The fire-test-response characteristics determined by this test method are affected by the thickness of the material used as test specimen, whether as a plaque or as coating on a wire or cable. The diameter of the wire or cable used will also affect the test results.
A radiant exposure is used as an energy source for this test method. This type of source has been used for comparison with heat release rate and flame spread studies of insulating materials constructed into cables when burning in a vertical cable tray configuration (Test Methods D5424 and D5537) (2-9). No definitive relationships have been established.
The value of heat release rate corresponding to the critical limit between propagating cable fires and non-propagating fires is not known.
This test method does not determine the net heat of combustion.
It has not been demonstrated that this test method is capable of predicting the response of electrical or optical fiber cables in a full scale fire. In particular, this test method does not address the self-extinguishing characteristics of the cables in a full scale fire.
1. Scope
1.1 This is a fire-test-response standard.
1.2 Several fire-test-response characteristics, including the time to sustained flaming, heat release rate, total heat released, effective heat of combustion, and specific extinction area; are measured or calculated by this test method at a constant radiant heating flux. For specific limitations see also 5.7 and Section 6.
1.3 The tests are conducted by burning the electrical insulating materials contained in electrical or optical fiber cables when the cable test specimens, excluding accessories, are subjected to radiant heat.
1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability or regulatory limitations prior to use. For specific precautionary statements, see Section 7.
1.6 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.
1.7 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests.

2. Referenced Documents (purchase separately)
ASTM Standards
D618 Practice for Conditioning Plastics for Testing
D1711 Terminology Relating to Electrical Insulation
D5424 Test Method for Smoke Obscuration of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
D5485 Test Method for Determining the Corrosive Effect of Combustion Products Using the Cone Corrosimeter
D5537 Test Method for Heat Release, Flame Spread, Smoke Obscuration, and Mass Loss Testing of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration
E176 Terminology of Fire Standards
E691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method
E906 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using a Thermopile Method
E1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
E1474 Test Method for Determining the Heat Release Rate of Upholstered Furniture and Mattress Components or Composites Using a Bench Scale Oxygen Consumption Calorimeter
CSA Standard
CSA C22.2 No. 0.3, FT4, Vertical Flame Tests: Cables in Cable Trays, Section 4.11.4 in C22.2 No. 0.3, Test Methods for Electrical Wires and Cables
IEC Standards
IEC60695-5-2 Fire Hazard Testing. Part 5: Assessment of Potential Corrosion Damage by Fire Effluent - Section 2: Guidance on the Selection and Use of Test Methods
IEEE Standard
IEEE1202 Standard for Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies, IEEE Standard 1202
ISO Standards
ISO11907-4 Plastics--Smoke Generation--Determination of the Corrosivity of Fire Effluents--Part 4: Dynamic Decomposition Method Using a Conical Radiant Heater
NFPA Standard
NFPA262 Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces
OSHA Standard
OSHA191.1450 Occupational Exposure to Hazardous Chemicals in Laboratories
UL Standards
ANSI/UL1685 Standard Vertical Tray Fire Propagation and Smoke Release Test for Electrical and Optical Fiber Cables
Index Terms
cable; cone calorimeter; electrical cable; electrical insulation; fire; fire-test response; heat release; heat release rate; optical fiber cable; oxygen consumption calorimetry; smoke obscuration; Cone calorimeter; Electrical fiber cable; Electrical insulating materials; Fire-test response; Heat release; Insulating materials; Optical fiber/cable/conduit; Smoke obscuration;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 今天澳门一码一肖 | 2025年澳门今晚开奖结果 | 澳门一码一码100准确 | 白小姐一肖一码开今晚 | 澳门最神秘的龙门客栈 | 今晚澳门特马必中一肖:精选解释解析落实 | 006677夜明珠效测 | 2025澳门正版资料免费中 | 香港资料大全正版资料使用方法 | 今晚澳门必中一肖一码二四六 | 新快报买马图今期 | 香港小鱼儿论坛网站 | 澳门特中一肖一码 | 118网址之家l258c校园片 | 澳门管家婆四肖选一肖期期准 | 九点公开验证一码最准资料 | 澳门最快最准期期资料权威精准数据下载 | 新奥2025年免费资料大全 | 正版49图库 | 澳门正版资料大全免费手机下载 | 澳门正版资料周公神算 | 新澳精准资料免费提供025期5 | 澳门今晚开特马免费 | 新澳今晚开奖结果2025年8月 | 金光佛高手资料区 | 2025澳门国际幻彩大巡游 | 49图库全新版本港澳台资料安卓下 | 澳门4949开奖结果最快 | 澳门精准免费资料查看 | 新澳门天天彩2025年全年资料 | 最准一肖一码一一中一特正版全年免费资料 | 今晚澳门必中一肖一码三期102 | 118免费大全资料 | 香港6合开奖结果+开奖记录今晚下载 | 2025澳门免费资料大公开 | 二四六好彩天天免费资料 | 新澳2025年精准资料32期 | 2025澳门天天彩正版免费 | 澳门今晚开什么号021期25 | 正版澳门资料免费大全免费版下载 | 2025年新澳门夭夭好彩 |