NFPA 430 液態和固態氧化物的貯存規范

放大字體  縮小字體 發布日期:2012-02-09   瀏覽次數:76  分享到: 分享到騰訊微博
NFPA 430 液態和固態氧化物的貯存規范
NFPA 430 Code for the Storage of Liquid and Solid Oxidizers
NFPA 430 液態和固態氧化物的貯存規范
 
1.1.1 This code shall apply to the storage and handling of oxidizers that are liquid or solid at ambient conditions.
1.1.1.1 This code shall not apply to the storage of solid and liquid oxidizers for normal use on the premises of one- and two-family dwellings.
1.1.1.2 Separate chapters shall specify requirements for storage of oxidizers by class where the quantities stored are greater than the stated minimums.
1.1.1.3* For quantities of a class of oxidizer that are less than the minimum covered by the separate chapter for that class, those parts of that chapter pertaining to fire prevention and compatibility as well as all of Chapter 4 of this code shall be used as requirements.
1.1.2 This code shall not apply to explosives or blasting agents, which are covered by NFPA 495, Explosive Materials Code; to ammonium nitrate, which is covered in NFPA 490, Code for the Storage of Ammonium Nitrate; or to organic peroxides, which are covered in NFPA 432, Code for the Storage of Organic Peroxide Formulations.
1.1.3 The quantity and arrangement limits in this code shall not apply to the storage of oxidizers in process areas at plants where oxidizers are manufactured.
1.1.3.1 This code shall not apply to the storage of solid and liquid oxidizers in existing buildings used for the storage of oxidizers at manufacturing plants.
1.1.4 The quantity and arrangement limits in this code shall not apply to facilities that use ammonium perchlorate in the commercial manufacture of large-scale rocket motors.
 
Get the facts to avoid dangers when storing oxidizers!
NFPA 430 provides requirements for the safe storage of liquid and solid oxidizers including, commercially available strengths of oxidizers used for water treatment. Proper storage and handling will decrease the risks of explosion, spontaneous ignition of combustible materials, rapid decomposition, and other hazardous situations.
The 2004 edition of NFPA 430 is a complete revision of the document and contains many significant changes, including
·   Requirements to restrict storage exposure from excessive temperatures
·   A major revision of the sprinkler requirements for Class 3 oxidizers stored in sprinklered buildings
·   A revision of the allowable storage amounts for Class 1-3 oxidizers that generally reduces the amount of material that can be stored without using sprinkler protection.
·   A revision of the requirements for storage in mercantile occupancies.
·   Annex material to assist emergency responders so they have a better understanding of the hazards and behavior of oxidizers.
·   Annex material on the physical properties of oxidizers.
(Approx. 27 pp., 2004)

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 澳门6合和彩正版下载 | 2025澳门今晚一肖一码准吗 | 今晚白小姐四不像图94期 | 四肖期期期准四肖期期准 | 澳门三肖三期必出一期 | 2025香港本期开奖号码解析 | 天下釆彩与你同行资料 | 二肖二码长期免费公开 | 2025年澳门正版资料有哪些 | 天下彩天空彩彩票资料大全下载 | 澳门彩今晚开斤么 | 澳门资料金牛版下载 | 三期必开一肖期期准免费资料 | 澳门一肖一码100%准确明晚 | 白小姐三码三期必开一码 | 2025香港免费精准资料 | 一码一肖100准是真是假?解密内幕 | 2025年1一154期资料 | 澳门周公资料网站 | 澳门水果奶奶799288com最新版下载 | 2025新澳开奖结果 | 澳门天天彩资料正版免费特色 | 118彩色厍图库彩图开奖号码 | 澳门天天彩免费资料大全免费查询下载 | 2025年澳门正版资料大全记录 | 蓝月亮精选资料期期惟 | 澳门今晚必中一码2025 | 管家婆2025资料图片大全 | 王中王一肖一特一中的教学内容 | 图片2025新图片 | 49图库官方下载 | 澳门正版资料49853 | 2025年澳门今晚必开一肖一特 | 三肖三期必出特马详解 | 香港最快最准资料免费 | 以及拥有全网最新原创的:澳门正版资料免费大全公开 | 澳门资料金牛版app免费下载安装 | 2025年新澳彩开奖结果 | 一码一肖100准打开码结果(中国)网站 | 澳门六开彩天天免费资料 | 上海女童 |