ASTM C1014噴施的礦物纖維吸熱和吸音絕緣材料標(biāo)準(zhǔn)規(guī)范

放大字體  縮小字體 發(fā)布日期:2012-02-13   瀏覽次數(shù):327  分享到: 分享到騰訊微博
ASTM C1014噴施的礦物纖維吸熱和吸音絕緣材料標(biāo)準(zhǔn)規(guī)范
ASTM C1014 Standard Specification for Spray-Applied Mineral Fiber Thermal and Sound Absorbing Insulation
ASTM C1014噴施的礦物纖維吸熱和吸音絕緣材料標(biāo)準(zhǔn)規(guī)范
This specification covers the composition and the physical properties of spray-applied mineral fiber thermal and sound absorbing insulation. These mineral fibers shall be pneumatically conveyed to a spray nozzle where they are mixed with water. These mineral fibers shall have a binder either pre-mixed with the fibers or added at the spray nozzle with the water. The basic material shall be fibers made form mineral substances such as rock, slag or glass processed from the molten state into a fibrous form. All self-supporting applications of the insulation shall have a minimum adhesive/cohesive strength of five times the weight of the material under the testing plate when tested. The insulation shall not spall, crack, or delaminate when the substrate is deflected. The insulation shall have a maximum flame spread index of 25 and a maximum smoke developed of 50 when tested. The insulation shall have a weight loss not greater than 5 %, nor shall there be a flaming ignition when tested. When tested, the insulation shall have growth no greater than that observed on the white birch tongue depressor comparative material. The spray-applied mineral fiber shall show no greater corrosion than the comparative plate in contact with the sterile cotton for the particular metal substrate to which classification is desired. A detectable odor of a strong objectionable nature recorded by more than two of the five panel members shall constitute rejection of the material when tested. Density and thickness of each sample tested shall be determined in accordance with test methods E 605. The adhesive/cohesive strength, thermal resistance, effects of substrate deflection, water vapor sorption, surface burning characteristics, smoldering combustion, fungi resistance, particular metal substrate corrosion, sound absorption, odor emission, and air errosion characteristics shall be tested to meet the requirements prescribed.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers the composition and the physical properties of spray-applied mineral fiber thermal and sound absorbing insulation.
1.2 These mineral fibers shall be pneumatically conveyed to a spray nozzle where they are mixed with water. These mineral fibers shall have a binder either pre-mixed with the fibers or added at the spray nozzle with the water.
1.3 The spray-applied mineral fiber insulation is intended for use in building constructions at ambient conditions.
1.4 This is a material specification only and is not intended to cover methods of application that are supplied by the manufacturer.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
C168 Terminology Relating to Thermal Insulation
C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
C423 Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
C665 Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing
C1104/C1104M Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation
C1114 Test Method for Steady-State Thermal Transmission Properties by Means of the Thin-Heater Apparatus
C1149 Specification for Self-Supported Spray Applied Cellulosic Thermal Insulation
C1304 Test Method for Assessing the Odor Emission of Thermal Insulation Materials
C1338 Test Method for Determining Fungi Resistance of Insulation Materials and Facings
C1368 Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature
E84 Test Method for Surface Burning Characteristics of Building Materials
E605 Test Methods for Thickness and Density of Sprayed Fire-Resistive Material (SFRM) Applied to Structural Members
E756 Test Method for Measuring Vibration-Damping Properties of Materials
E759 Test Method for Effect of Deflection on Sprayed Fire-Resistive Material Applied to Structural Members
E795 Practices for Mounting Test Specimens During Sound Absorption Tests
E859 Test Method for Air Erosion of Sprayed Fire-Resistive Materials (SFRMs) Applied to Structural Members
Index Terms
mineral fiber insulation; sound absorbing; spray-applied; thermal; Mineral fiber insulation--specifications; Sound absorbing/insulating materials/applications--specifications; Spray-applied thermal insulation--specifications; Thermal insulating materials--specifications; Acoustical materials/applications--specifications;

  詳情請咨詢
  防火資源網(wǎng)-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網(wǎng)"的所有作品,由<防火資源網(wǎng)>整理編輯,任何組織未經(jīng)<防火資源網(wǎng)>及其擁有者授權(quán),不得復(fù)制、轉(zhuǎn)載、摘編或利用其它方式應(yīng)用于任何商業(yè)行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網(wǎng)站首頁 | 廣告服務(wù) | 關(guān)于我們 | 聯(lián)系方式 | 服務(wù)協(xié)議 | 版權(quán)聲明 | 網(wǎng)站地圖 | 友情鏈接 | 網(wǎng)站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 2025买马12生肖号码图高清 | 二四六精版免费大全 | 澳门金牛版免费资料网最新版2025 | 彩图全解道德经(彩图精装) | 澳门2025免费资料大全 | 彩图开奖号码 | 马会传真论13297cc | 新澳2025最新资料 | 澳门最准的一码一码100准 | 下载港澳宝典626250到 | 管家婆一码一肖与中奖的奥秘 | 澳门一肖一码精准 | 澳门最精准免费全年资料大全 | 黄大仙一肖一码必中一期 | 2025澳门传真澳门传真网站 | 2025港澳宝典正版资料下载 | 澳门精准免费资料大全最新权威版本下载 | 澳门今晚出啥码呢 | 澳门今期正版四不像图片 | 澳门一肖一码精准资料 | 澳门霸王四肖 | 2025正版澳门全年免费手机看资料82 | 彩图开奖号码 | 新澳2025最新资料 | 澳门凤凰精选三肖三码 | 2025年香港今晚特马开什么 | 澳门内部资料和公开资料 | 正版资料大全2025 | 黄大仙心水论坛 | 新澳正版最精准资料与内部资料 | 澳门六开彩资料查询最新 | 澳门正版资料大全免费下载 | 今晚六台彩开什么号码 | 澳门最精准正最精准龙门客栈免费 | 下载彩图宝库宝典最新版 | 2025澳门天天六开彩今晚开奖号码 | 澳门一码一肖一特一中直播 | 新澳门2025年资料大全管家婆 | 2025年香港免费资料最新版本 | 最准一肖一码一一中一特正版全年免费资料 | 2025年新澳版资料正版图库 |