ASTM D4566 Standard Test Methods for Electrical Performance Properties of Insulations and Jackets for Telecommunications Wire and Cable
ASTM D4566遠程通信電線和電纜用絕緣體和套管的電氣性能特性的標準試驗方法
Electrical tests, properly interpreted, provide information with regard to the electrical properties of the insulation. The electrical test values give an indication as to how the insulation will perform under conditions similar to those observed in the tests. Electrical tests may provide data for research and development, engineering design, quality control, and acceptance or rejection under specifications.
1. Scope
1.1 These test methods cover procedures for electrical testing of thermoplastic insulations and jackets used on telecommunications wire and cable and for the testing of electrical characteristics of completed products. To determine the procedure to be used on the particular insulation or jacket compound, or on the end product, reference should be made to the specification for the product.
1.2 The test methods appear in the following sections of this standard:
Test Method
Sections
Electrical Tests of Insulation—In-Process
4-8
DC proof test
8
Insulation defect or fault rate
7
Spark test
6
Electrical Tests of Completed Wire and Cable
9-51
Attenuation
24
Attenuation, effects due to aging
31
Attenuation, effects due to elevated temperature
29
Attenuation, effects due to humidity
30
Attenuation to crosstalk ratio—far end (ACR-F)
28
Attenuation to crosstalk ratio—near end (ACR-N)
26
Capacitance deviation
19
Capacitance difference
20
Capacitance unbalance, Pair-to-ground (CUPG)
22
Capacitance unbalance, Pair-to-pair (CUPP)
21
Capacitance unbalance, Pair-to-support wire
23
Characteristic Impedance—Method 1 Propagation constant
and capacitance
47
Characteristic Impedance—Method 2, Single-ended
measurements
48
Characteristic Impedance—Method 3 Least Squares Function Fit
49
Coaxial capacitance (capacitance to water)
17
Conductor continuity
11
Conductor resistance (CR)
13
Conductor resistance unbalance (CRU of pairs)
15
Continuity of other metallic elements
12
Crosses test (continuity between wires of different pairs)
35
Crosstalk loss, far-end
27
Crosstalk loss, near-end
25
DC proof test, Core-to-internal shield (screen)
40
DC proof test, Core-to-shield
38
DC proof test, Core-to-support wire
39
DC proof test, Internal shield (screen)-to-shield
41
DC proof test, Other required isolations
42
DC proof test, Wire-to-wire
37
Fault rate test (air core only)
33
Insulation resistance (IR)
32
Jacket voltage breakdown rating test
36
Mutual capacitance (CM)
18
Mutual conductance
16
Phase Constant
44
Phase Delay
45
Phase Velocity
46
Resistance of other metallic cable elements
14
Shorts test (continuity between wires of a pair)
34
Structural Return Loss and Return Loss
50
Unbalance attenuation (conversion losses)
51
Voltage surge test
43
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Sections 6 and 37.
4.1 In-process electrical tests are used primarily as process control tools in an attempt to minimize the number and magnitude of problems detected at final test of completed cable.
9.1 Electrical tests of completed wire and cable may include verification of some or all of the properties in accordance with Sections 11 through 51.

2. Referenced Documents (purchase separately)
ASTM Standards
B193 Test Method for Resistivity of Electrical Conductor Materials
D150 Test Methods for AC Loss Characteristics and Permittivity (Dielectric Constant) of Solid Electrical Insulation
D1711 Terminology Relating to Electrical Insulation
D2633 Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable
D3426 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials Using Impulse Waves
D5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation
E29 Practice for Using Significant Digits in Test Data to Determine Conformance with Specifications
ANSI Standard
ANSI/IEEEStandard100 IEEE Standard Dictionary of Electrical and Electronics Terms
IEC Standard
IEC61156-1 Multicore and Symmetrical Pair/Quad Cables for Digital Communications--Part 1: Generic Specification
Index Terms
aging; attenuation; attenuation to crosstalk ratio near-end; attenuation to crosstalk ratio far-end; capacitance deviation; capacitance difference; capacitance unbalance pair-to-pair; capacitance unbalance pair-to-ground; capacitance unbalance pair-to-support wire; characteristic impedance; coaxial capacitance; conductor resistance; conductor resistance unbalance; continuity; conversion loss; crosses; crosstalk loss—far end; crosstalk loss—near end; dc proof test; equal level far-end crosstalk; equal level unbalance attenuation far-end; equal level unbalance attenuation near-end; equal level longitudinal conversion transfer loss (EL LCTL); equal level transverse conversion transfer loss (EL TCTL); fault rate test; humidity; insulation defect; insulation resistance; jacket voltage breakdown; longitudinal conversion loss (LCL); longitudinal conversion transfer loss (LCTL); mutual capacitance; mutual conductance; phase constant; phase delay; phase velocity; shorts test; spark test; structural return loss; transverse conversion loss (TCL); transverse conversion transfer loss (TCTL); unbalance attenuation far-end; unbalance attenuation near-end; voltage surge test; Aging; Attenuation; Capacitance difference/deviation/unbalance; Characteristic impedance; Coaxial capacitance; Communications; Conductor continuity/resistance; Cross section data/analysis--insulation; D-C voltage test; Defects; Spark testing; Structural return loss; Telecommunications; Thickness--electrical insulating materials; Voltage surge test; Electrical performance; Fault rate; Impedance; Jacket voltage breakdown; Insulated wire and cable; Insulation adhesion//compression//shrinkback; Insulation defects; LCL/LCTL (longitudinal conversion/transfer loss); Insulation resistance; Jacket bonding//notch//peel//shrinkback//slip strength; Melt flow; Mutual conductance/capacitance; Oil immersion; Performance--electrical insulation; Phase delay/constant/velocity; Shorts test;

  詳情請咨詢
  防火資源網-阻燃防火測試中心
  電話:(+86)0592-5056213
  傳真:(+86)0592-5105807
  郵件:firetest@firetc.com

凡注明"防火資源網"的所有作品,由<防火資源網>整理編輯,任何組織未經<防火資源網>及其擁有者授權,不得復制、轉載、摘編或利用其它方式應用于任何商業行為。

 
 
[ 防火測試中心搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]  [ 返回頂部 ]

 

 
 
推薦防火測試
推薦圖文
點擊排行
 
 
網站首頁 | 廣告服務 | 關于我們 | 聯系方式 | 服務協議 | 版權聲明 | 網站地圖 | 友情鏈接 | 網站留言 | 舊版本 | 閩ICP備09009213號
?2019-2021 FIRETC.COM All Rights Reserved ? 備案號:閩ICP備09009213號-1在線客服 點擊QQ交談/留言 點擊QQ交談/留言
主站蜘蛛池模板: 澳门最快最准的资料免费 | 2025新奥精准正版资料 | 今晚澳门开最准一肖一码 | 2025年澳门全年资料免费大全 | 六合慈善779942.C0m | 2025澳门天天六开彩今晚开奖号码 | 澳门资料免费大全新澳好彩免费资料查询2025 | 2025管家婆一码一肖资料 | 2025澳门正版资料大全资料生肖卡 | 2025年澳门今晚特马开什么号码 | 118彩色厍图库彩图移动客户端下载 | 澳门简介资料大全 | 马报 | 今天澳门一码一肖 | 以及拥有全网最新原创的:澳门正版资料免费大全公开 | 管家婆三期必开一期2025 | 澳门精准三肖三码三期必出一期 | 2025新奥开奖历程详录:精准数据解读 | 7777788888王中王论坛 | 澳门六开彩开奖结果历史查询 | 澳门天天彩免费资料大全免费查询下载 | 澳门精准免费资料大全下载 | 白小姐三码期期准白小姐 | 神算子玄机心水资料论坛 | 49图库老旧版本大全 | 2025年澳门今晚特马开什么号码 | 香港资料正版大全2025 | 正版资料免费2025 | 三期必开一期三期必出特电视剧在线观看 | 澳门今晚必中四不像图 | 白小姐六肖期期准王中王 | 2025澳门六开彩最新资料查询 | 2025香港免费资料大全100 | 以及香港/澳门资料大全 | 天下彩(9944cc)天下彩图 | 今晚开什么特马2025年 | 最准一肖一码100%最准软件 | 澳门赤兔马料免费公开资料大全1 | 2025上半年教资笔试卢姨团队正版资料 | 香港资料大全+正版资料 | 2025正版资料大全完整版搜狗 |